Protection Devices

We provide a wide range of electrical protection devices, including MCBs, MCCBs, RCBs, RCBOs, and more.
These devices ensure safety by protecting against overloads, short circuits, and earth faults in residential, commercial, and industrial applications.

Circuit Breakers

MCCB (Compact NS)

Molded Case Circuit Breaker rating from 630 to 3200A, 3-pole and 4-pole construction Fixed or drawout versions. integrated Micrologic protection unit (A,E,P) Breaking capacity: 50 & 70 kA Complete selectivity with lcs=100%Icu Suitable for 690V applications standard: Conforms to IEC 60947- 2 & 3

ACB (MasterPactNW)

Air Circuit Breaker ratings from 800 to 6300 A 3-pole and 4-pole construction Fixed or drawout versions. integrated Micrologic protection unit (A,E,P,H) Complete selectivity with lcs=100%Icu Breaking capacity: 42 & so & 65 kA Suitable for 1000V applicationsstandard: Conforms to IEC 60947- 2 & 3

ACB Air (EasyPact MVS)

Air Circuit Breaker ratings from 630 to 4000 A 3-pole and 4-pole construction
Fixed or drawout versions. integrated Micrologic protection unit CA.E) Complete selectivity with lcs=100%Icu Breaking capacity: so & 65 kA Suitable for 690V applications standard

MCBACTl9

Miniature Circuit Breakers rating from 1 to 125 A 1. 2, 3 and 4 pole versions Thermal-Magnetic protection unit Breaking capacity: 6 & 10 & 15 & 25 kA standards IEC/EN 60898-1 and IEC/EN 60947-2

MCCB (Eazypact EZC)

Molded Case Circuit Breaker rating from 16 to 630A, fixed setting 1,2,3,4pole construction Fixed versions. integrated: Thermal Magnticor protection unit Breaking capacity: 15 & 25 & 36 & 50 kA Complete selectivity with lcs=50%1cu Suitable for 690V applications standard: Conforms to IEC 60947- 2 & 3

MCCB (Compact NSX & Eazypact CVS)

Molded Case Circuit Breaker rating from 16 to 630A, 3-pole and 4-pole construction
Fixed & plug-in & drawout versions. integrated:Thermal-Magnticor or electronic protection unit Breaking capacity: 25 & 36 & so & 70 kA Complete selectivity with lcs=100%1cu Suitable for 690V applications standard: Conforms to IEC 60947- 2 & 3

Vigi for Acti9-iC60

Residual current add-on devices up to 63 A for Acti9 iC60 MCB (A9F74 & A9F84)
sensitivity 30, 100, 300, 500 and 1000 mA Standard: IEC EN 61009-1

RCBOACTl9

Residual current circuit breakers up to 100 A Residual current circuit breakers with integrated overcurrent protection up to 40 A sensitivity 30, and 300 mA
Standard: IEC/EN 61009-2-1 /BS EN 61009-1

RCCB ACTl9 iLD

Residual current circuit breakers up to 100 A sensitivity 30, 100, 300 and 500 mA standard IEC EN 61008-1

ISWACTl9

Switch disconnector up to 125 A Standard: EN 60669-2-4, IEC 669-2-4 IEC 947-3 for 40 to 125 A

Contactors

TeSysF

Contactors to control motors up to 1000 A (500 kW / 440 V) range from 115 A to 1000 A for AC-3 and from 200 A to 2600 A for AC-1 3-pole and 4-pole versions standards IEC 60947-5-1/UL 508.

TeSys D

Contactors to control motors ( 4K to 75KW) @400VAC AC-3 / AC-1 range from 9 A to 150 A (inductive motor) and from 20 A to 200 A (resistive loads) 3 pole and 4-pole versions standards .

TeSys K

Compact contactors to control motors 6, 9, 12, and 16 A (7.5 kW / 400 V) Range: 2.2 kW, 4.5 kW, 5.5 kW in AC3 Applications industry, infrastructure and building standards IEC 60947/UL.

Overload Relays

TeSys LR9 ,Electronic Overload Relays

from 0.1 to 630 amps
for Motor protection & control in material handling, HVAC, lifts & escalators, textiles, water, food and beverage. /Power switching, lighting, capacitor switching, and similar.
Class 10, Class 20

TeSys LRD, Thermal overload relays

coordinated with TeSys D contactors, to protect from overloads motors up to 150 A (75 kW / 400 V) Class 10 A & class 20.

TeSys LR2K , Thermal overload relays

coordinated with TeSys K contactors, to protect from overloads motors up to 16 A (5.5 kW / 400 V) Class 10 A

Motor control and protection

Enclosed DOL Starter

from 0.25 to 7.5 kW ( 400V AC), Degree of protection IP65 standard to IEC 60947-4-1

TeSysGV2P & GV3P

Thermal-magnetic motor starter up to 65 A (30 kW/ 400-415 V) IEC 947-2 and IEC 947-4-1 / UL 508 Listed, CSA Certified, and CE Marked

TeSysGV2M & GV3M

Thermal-magnetic motor starter up to 65 A (30 kW/ 400-415 V) IEC 947-2 and IEC 947-4-1 / UL 508 Listed, CSA Certified, and CE Marked

Surge Arrestors

Surge Protection Devices - Acti9

Modular surge arresters with withdrawable cartridges from 8 kA to 65 kA
standard IEC/EN 61643-11:2011

Relays & Timers

Zelio Control & Measurement Relays

Wide monitoring parameters: phase, current, voltage, liquid level, frequency, speed, temperature and pump control. Monitoring and Control Relays RM17 – RM22 – RM35. Standards: EN60255-l, IEC60255-l 

Impulse Relays - Acti9-iTL

DIN rail Impulse relays Rating: 16, 32 A with lP, 2P, 3P or 4P standards: EN 60-669-1 & EN 60-669-2-2

Zelio Control Relays

Zelio RSL , slim interface relays Zelio RSB , interface relays Zelio RXM , 

Zelio Control Relays

Zelio RSL , slim interface relays Zelio RSB , interface relays Zelio RXM , 

Fuses & Fuse Holders

Fuse Link Type D & C

Available in different characteristics ,rated currents, breaking capacities (KA). shapes and sizes Standards: DIN EN 60269-1, DIN EN 60269-3 IEC 60269-1, IEC 60269-2

Acti 9 Fuse Holders

Acti9 SBI, Fuse holder with indicator light provide exceptional levels of protection to electrical circuits for all industrial applications that require a high breaking capacity.
can use both gG (overload and short-circuit protection) and aM (only short-circuit protection) fuse

Acti 9 Fuse Holders

Acti 9 STI, Fuse-carrier disconnector Disconnection of all poles are guaranteed for the 2P, 3P, and 3P+N versions during factory assembly. can use both gG (overload and short-circuit protection) and aM (only short-circuit protection) fuse

Fuse Switch Disconnector "KVL-1 3pM10"

Available in different characteristics ,rated currents , breaking capacities (KA) , shapes and sizes Standard: PN-IEC 60269-2 , VOE 0636-20TI, IEC 60269-1, IEC
60269-2

Fuse link base "PK 1 M10-M10 3p S"

Screw mounting fuse base
Standards IEC 60269-2

Fuse link base "PK 00 2M6-2M6 lp S"

Standards IEC 60269-2
Screw mounting fuse bases for NH fuses
Standards IEC 60269-2

Fuse Switch Disconnector "KVL-1 3pM10"

Fuse Holder for NH fuses- disconnectors
standards IEC/EN 60947-3

Fuse link base "PK 1 M10-M10 3p S"

Screw mounting fuse base
Standards IEC 60269-2

Fuse link base "PK 00 2M6-2M6 lp S"

Standards IEC 60269-2
Screw mounting fuse bases for NH fuses
Standards IEC 60269-2

Fuse Link Type NH

Available in different characteristics ,rated currents , breaking capacities (KA) , shapes and sizes Standard: PN-IEC 60269-2 , VOE 0636-20TI, IEC 60269-1, IEC60269-2