{"title":"Overload Relays","description":"","products":[{"product_id":"thermal-overload-relay-tesys-deca-690vac-0-1-to-0-16a-1no1nc-class-10a-screw-clamp","title":"Thermal overload relay, TeSys Deca, 690VAC, 0.1 to 0.16A, 1NO+1NC, class 10A, screw clamp","description":"\u003cp\u003eTeSys LRD thermal overload relay, 0.16A\/690V, thermal setting range 0.1-0.16A, tripping class 10A, for protection of 3-phase motors less than 0.06kW@400V. Differential device with phase failure (loss). It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D09-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B106 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs\/Reach).\u003c\/p\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD01.pdf?v=1727348766\"\u003e\n\u003cp\u003eView More Details\u003c\/p\u003e\n\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46629866668272,"sku":"00102001","price":22.6,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD01_Image_4000x4000_190eb3c8-41c4-4589-a221-37a4a7159556.png?v=1727603079"},{"product_id":"thermal-overload-relay-tesys-deca-690vac-0-16-to-0-25a-1no1nc-class-10a","title":"Thermal overload relay, TeSys Deca, 690VAC, 0.16 to 0.25A, 1NO+1NC, class 10A","description":"TeSys LRD thermal overload relay, 0.25A\/690V, thermal setting range 0.16-0.25A, tripping class 10A, for protection of 3-phase motors 0.06kW@400V. Differential device with phase failure (loss). It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D09-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B106 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs\/Reach).\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD02.pdf?v=1727348805\"\u003e\u003cp\u003eView More Details\u003c\/p\u003e\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46629866701040,"sku":"00102003","price":22.6,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD02C_Image_4000x4000_fdc572c7-0785-43ad-bb61-63d7ac088261.png?v=1727603085"},{"product_id":"thermal-overload-relay-tesys-deca-690vac-0-25-to-0-4a-1no1nc-class-10a-screw-clamp","title":"Thermal overload relay, TeSys Deca, 690VAC, 0.25 to 0.4A, 1NO+1NC, class 10A, screw clamp","description":"TeSys LRD thermal overload relay, 0.4A\/690V, thermal setting range 0.25-0.4A, tripping class 10A, for protection of 3-phase motors 0.09kW@400V. Differential device with phase failure (loss). It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D09-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B106 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs\/Reach).\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD03.pdf?v=1727348867\"\u003e\u003cp\u003eView More Details\u003c\/p\u003e\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46629866733808,"sku":"00102005","price":22.6,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD03C_Image_4000x4000_5d559af1-55df-4adb-9d94-a233644ac236.png?v=1727603091"},{"product_id":"thermal-overload-relay-tesys-deca-690vac-0-4-to-0-63a-1no1nc-class-10a-screw-clamp","title":"Thermal overload relay, TeSys Deca, 690VAC, 0.4 to 0.63A, 1NO+1NC, class 10A, screw clamp","description":"TeSys LRD thermal overload relay, 0.63A\/690V, thermal setting range 0.4-0.63A, tripping class 10A, for protection of 3-phase motors 0.12-0.18kW@400V. Differential device with phase failure (loss). It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D09-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B106 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs\/Reach).\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD04.pdf?v=1727348879\"\u003e\u003cp\u003eView More Details\u003c\/p\u003e\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46629866766576,"sku":"00102007","price":22.6,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD04C_Image_4000x4000_e7ea2653-1a5e-43bf-b1c6-feca796d37fb.png?v=1727603097"},{"product_id":"thermal-overload-relay-tesys-deca-690vac-0-63-to-1a-1no1nc-class-10a-screw-clamp","title":"Thermal overload relay, TeSys Deca, 690VAC, 0.63 to 1A, 1NO+1NC, class 10A, screw clamp","description":"TeSys LRD thermal overload relay, 1A\/690V, thermal setting range 0.63-1A, tripping class 10A, for protection of 3-phase motors 0.25-0.37kW@400V. Differential device with phase failure (loss). It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D09-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B106 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs\/Reach).\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD05.pdf?v=1727348919\"\u003e\u003cp\u003eView More Details\u003c\/p\u003e\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46629866799344,"sku":"00102009","price":19.8,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD05L_Image_4000x4000_261a175e-52c3-4183-896d-d86287ef7232.png?v=1727603106"},{"product_id":"thermal-overload-relay-tesys-deca-690vac-1-to-1-6a-1no1nc-class-10a-screw-clamp","title":"Thermal overload relay, TeSys Deca, 690VAC, 1 to 1.6A, 1NO+1NC, class 10A, screw clamp","description":"\u003cp\u003eTeSys LRD thermal overload relay, 1.6A\/690V, thermal setting range 1-1.6A, tripping class 10A, for protection of 3-phase motors 0.55kW@400V. Differential device with phase failure (loss). It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D09-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B106 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs\/Reach).\u003c\/p\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD06.pdf?v=1727349082\"\u003e\n\u003cp\u003eView More Details\u003c\/p\u003e\n\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46629866832112,"sku":"00102011","price":19.8,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD06L_Image_4000x4000_15970fbf-b829-4860-88e1-422f510a7953.png?v=1727603115"},{"product_id":"thermal-overload-relay-tesys-deca-690vac-1-6-to-2-5a-1no1nc-class-10a-screw-clamp","title":"Thermal overload relay, TeSys Deca, 690VAC, 1.6 to 2.5A, 1NO+1NC, class 10A, screw clamp","description":"TeSys LRD thermal overload relay, 2.5A\/690V, thermal setting range 1.6-2.5A, tripping class 10A, for protection of 3-phase motors 0.75kW@400V. Differential device with phase failure (loss). It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D09-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B106 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs\/Reach).\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LC1D09M7.pdf?v=1726725043\"\u003e\u003cp\u003eView More Details\u003c\/p\u003e\u003c\/a\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD07.pdf?v=1727349132\"\u003e\u003cp\u003eView More Details\u003c\/p\u003e\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46629866864880,"sku":"00102013","price":19.8,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD07_Image_4000x4000_d7d61c8e-b222-4cc8-87ac-7fb27709a1f5.png?v=1727603123"},{"product_id":"thermal-overload-relay-tesys-deca-690vac-3p-2-5-to-4a-1no1nc-class-10a-screw-clamp","title":"Thermal overload relay, TeSys Deca, 690VAC, 3P, 2.5 to 4A, 1NO+1NC, class 10A, screw clamp","description":"TeSys LRD thermal overload relay, 4A\/690V, thermal setting range 2.5-4A, tripping class 10A, for protection of 3-phase motors 1.1-1.5kW@400V. Differential device with phase failure (loss). It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D09-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B106 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs\/Reach).\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD08.pdf?v=1727349165\"\u003e\u003cp\u003eView More Details\u003c\/p\u003e\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46629866897648,"sku":"00102015","price":19.8,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD08C_Image_4000x4000_319c92b5-dc13-46d7-9c0a-31dcf7c2b27a.png?v=1727603129"},{"product_id":"thermal-overload-relay-tesys-deca-690vac-3p-4-to-6a-1no1nc-class-10a-screw-clamp","title":"Thermal overload relay, TeSys Deca, 690VAC, 3P, 4 to 6A, 1NO+1NC, class 10A, screw clamp","description":"\u003cp\u003eTeSys LRD thermal overload relay, 6A\/690V, thermal setting range 4-6A, tripping class 10A, for protection of 3-phase motors 2.2kW@400V. Differential device with phase failure (loss). It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D09-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B106 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs\/Reach).\u003c\/p\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD10.pdf?v=1727349197\"\u003e\n\u003cp\u003eView More Details\u003c\/p\u003e\n\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46629866963184,"sku":"00102017","price":19.8,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD10C_Image-1_4000x4000_4c0b6a2f-2950-418a-8295-42bc43d1398c.png?v=1727603139"},{"product_id":"thermal-overload-relay-tesys-deca-5-5-8a-1no1nc-class-10a-screw-clamp","title":"Thermal overload relay,TeSys Deca,5.5-8A,1NO+1NC,class 10A,screw clamp","description":"\u003cp\u003eTeSys LRD thermal overload relay, 8A\/690V, thermal setting range 5.5-8A, tripping class 10A, for protection of 3-phase motors 3kW@400V. Differential device with phase failure (loss). It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D09-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B106 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs\/Reach).\u003c\/p\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD12.pdf?v=1727349277\"\u003e\n\u003cp\u003eView More Details\u003c\/p\u003e\n\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46629866995952,"sku":"00102019","price":19.8,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD12C_Image_AI-improved_2024_4000_a34a9a45-0a22-4362-bd92-0e9054ff8a6c.png?v=1727603147"},{"product_id":"thermal-overload-relay-tesys-deca-690vac-7-to-10a-1no1nc-class-10a-screw-clamp","title":"Thermal overload relay, TeSys Deca, 690VAC, 7 to 10A, 1NO+1NC, class 10A, screw clamp","description":"TeSys LRD thermal overload relay, 10A\/690V, thermal setting range 7-10A, tripping class 10A, for protection of 3-phase motors 4kW@400V. Differential device with phase failure (loss). It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D09-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B106 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs\/Reach).\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD14.pdf?v=1727349327\"\u003e\u003cp\u003eView More Details\u003c\/p\u003e\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46629867061488,"sku":"00102021","price":19.8,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/files_de7442b4-c59a-49e9-bc61-173d1b60cdcb.png?v=1727603151"},{"product_id":"thermal-overload-relay-tesys-deca-9-13a-1no1nc-class-10a-screw-clamp","title":"Thermal overload relay,TeSys Deca,9-13A,1NO+1NC,class 10A,screw clamp","description":"TeSys LRD thermal overload relay, 13A\/690V, thermal setting range 9-13A, tripping class 10A, for protection of 3-phase motors 5.5kW@400V. Differential device with phase failure (loss). It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D12-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B106 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs\/Reach).\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD16.pdf?v=1727349371\"\u003e\u003cp\u003eView More Details\u003c\/p\u003e\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46629867127024,"sku":"00102023","price":19.8,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD16_Image_AI-improved_2024_4000_fbc71bac-6e80-4b47-a907-d9b2339f16f6.png?v=1727603160"},{"product_id":"thermal-overload-relay-tesys-deca-12-18a-1no1nc-class-10a-screw-clamp","title":"Thermal overload relay,TeSys Deca,12-18A,1NO+1NC,class 10A,screw clamp","description":"\u003cp\u003eTeSys LRD thermal overload relay, 18A\/690V, thermal setting range 12-18A, tripping class 10A, for protection of 3-phase motors 7.5kW@400V. Differential device with phase failure (loss). It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D18-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B106 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs\/Reach).\u003c\/p\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD21.pdf?v=1727349429\"\u003e\n\u003cp\u003eView More Details\u003c\/p\u003e\n\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46629867159792,"sku":"00102025","price":21.8,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD21_Image_AI-improved_2024_4000_e1c4b351-0a25-4d48-bd53-78e8e0fa03ca.png?v=1727603169"},{"product_id":"thermal-overload-relay-tesys-deca-16-24a-1no1nc-class-10a-screw-clamp","title":"Thermal overload relay,TeSys Deca,16-24A,1NO+1NC,class 10A,screw clamp","description":"TeSys LRD thermal overload relay, 24A\/690V, thermal setting range 16-24A, tripping class 10A, for protection of 3-phase motors 11kW@400V. Differential device with phase failure (loss). It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D25-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B106 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs\/Reach).\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD22.pdf?v=1727349465\"\u003e\u003cp\u003eView More Details\u003c\/p\u003e\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46629867323632,"sku":"00102027","price":21.8,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD22L_Image_AI-improved_2024_4000_22e008d7-b33a-4682-892e-66944a931d86.png?v=1727603178"},{"product_id":"thermal-overload-relay-tesys-deca-23-32a-1no1nc-class-10a-screw-clamp","title":"Thermal overload relay,TeSys Deca,23-32A,1NO+1NC,class 10A,screw clamp","description":"TeSys LRD thermal overload relay, 32A\/690V, thermal setting range 23-32A, tripping class 10A, for protection of 3-phase motors 15kW@400V. Differential device with phase failure (loss). It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D25-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B205 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs\/Reach).\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD32.pdf?v=1727349498\"\u003e\u003cp\u003eView More Details\u003c\/p\u003e\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46629867389168,"sku":"00102029","price":44.35,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD32L_Image_AI-improved_2024_4000_5393cdf6-180b-47dc-a208-49bcdd4fc216.png?v=1727603186"},{"product_id":"thermal-overload-relay-tesys-deca-690vac-30-to-38a-1no1nc-class-10a-screw-clamp","title":"Thermal overload relay, TeSys Deca, 690VAC, 30 to 38A, 1NO+1NC, class 10A, screw clamp","description":"\u003cp\u003eTeSys LRD thermal overload relay, 38A\/690V, thermal setting range 30-38A, tripping class 10A, for protection of 3-phase motors 18.5kW@400V. Differential device with phase failure (loss). It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D32-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B106 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs\/Reach).\u003c\/p\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD35.pdf?v=1727349545\"\u003e\n\u003cp\u003eView More Details\u003c\/p\u003e\n\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46629867421936,"sku":"00102031","price":44.75,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD35C_Image_AI-improved_2024_4000_97ac19ad-c7de-40a9-9315-267ebc079b0c.png?v=1727603194"},{"product_id":"thermal-overload-relay-tesys-deca-690vac-23-to-32a-1no1nc-class-10a-everlink-screw-terminals","title":"Thermal overload relay, TeSys Deca, 690VAC, 23 to 32A, 1NO+1NC, class 10A, EverLink screw terminals","description":"\u003cp\u003eTeSys LRD thermal overload relay, 32A\/690V, thermal setting range 23-32A, tripping class 10A, for protection of 3-phase motors 15kW@400V. Differential device with phase failure (loss). It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by EverLink BTR screw terminals , it connects directly to the bottom terminals of 3-pole contactors LC1D40A-D80A. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD96560 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHs\/Reach).\u003c\/p\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD332.pdf?v=1727349580\"\u003e\n\u003cp\u003eView More Details\u003c\/p\u003e\n\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46629867487472,"sku":"00102032","price":50.8,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD332_Image_4000_beaa0c5a-dfad-4261-94dc-567ee616767d.png?v=1727603200"},{"product_id":"thermal-overload-relays-tesys-deca-23-32a-class-10a","title":"Thermal overload relays, TeSys Deca, 23...32A , class 10A","description":"TeSys LRD thermal overload relay, 32A\/1000V, thermal setting range 23-32A, tripping class 10A, for protection of 3-phase motors 15kW@400V. Differential device with phase failure (loss). It provides a thermal adjustement dial, a manual-automatic reset selector acting also as reset button, a trip test button for simulation of a tripping, a stop button, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D80-D95. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LA7D3064 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs\/Reach).\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD3353.pdf?v=1727349612\"\u003e\u003cp\u003eView More Details\u003c\/p\u003e\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46629867585776,"sku":"00102033","price":53.5,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD3353_Image_4000_02852751-5dc4-4794-acfd-f5a6a823fc05.png?v=1727603209"},{"product_id":"thermal-overload-relay-tesys-deca-690vac-17-to-25a-1no1nc-class-10a-everlink-btr-screw","title":"Thermal overload relay, TeSys Deca, 690VAC, 17 to 25A, 1NO+1NC, class 10A, EverLink BTR screw","description":"TeSys LRD thermal overload relay, 25A\/690V, thermal setting range 17-25A, tripping class 10A, for protection of 3-phase motors 11kW@400V. Differential device with phase failure (loss). It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by EverLink BTR screw terminals , it connects directly to the bottom terminals of 3-pole contactors LC1D40A-D80A. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD96560 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHs\/Reach).\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD325.pdf?v=1727349685\"\u003e\u003cp\u003eView More Details\u003c\/p\u003e\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46629867618544,"sku":"00102034","price":49.0,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD325_Image_4000_5e5d688b-fccb-4626-a923-602360b190d0.png?v=1727603215"},{"product_id":"thermal-overload-relays-tesys-deca-30-40a-class-10a-motor-protection","title":"Thermal overload relays, TeSys Deca, 30...40A, class 10A, motor protection","description":"TeSys LRD thermal overload relay, 40A\/1000V, thermal setting range 30-40A, tripping class 10A, for protection of 3-phase motors 18.5kW@400V. Differential device with phase failure (loss). It provides a thermal adjustement dial, a manual-automatic reset selector acting also as reset button, a trip test button for simulation of a tripping, a stop button, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D80-D95. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LA7D3064 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs\/Reach).\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD3355.pdf?v=1727349751\"\u003e\u003cp\u003eView More Details\u003c\/p\u003e\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46629867716848,"sku":"00102035","price":64.0,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD3355_Image_4000_c11efaae-6962-4efa-ab6e-10107b73e26d.png?v=1727603223"},{"product_id":"thermal-overload-relay-tesys-deca-690vac-30-to-40a-1no1nc-class-10a-everlink-btr-screw","title":"Thermal overload relay, TeSys Deca, 690VAC, 30 to 40A, 1NO+1NC, class 10A, EverLink BTR screw","description":"TeSys LRD thermal overload relay, 40A\/690V, thermal setting range 30-40A, tripping class 10A, for protection of 3-phase motors 18.5kW@400V. Differential device with phase failure (loss). It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by EverLink BTR screw terminals , it connects directly to the bottom terminals of 3-pole contactors LC1D40A-D80A. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD96560 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHs\/Reach).\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD340.pdf?v=1727349796\"\u003e\u003cp\u003eView More Details\u003c\/p\u003e\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46629867749616,"sku":"00102036","price":51.0,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD340_Image_4000_399770b0-f8d1-4dcb-bfac-ec78d18be055.png?v=1727603229"},{"product_id":"thermal-overload-relays-tesys-deca-37-50-a-class-10a","title":"Thermal overload relays, TeSys Deca, 37...50 A , class 10A","description":"TeSys LRD thermal overload relay, 50A\/1000V, thermal setting range 37-50A, tripping class 10A, for protection of 3-phase motors 22kW@400V. Differential device with phase failure (loss). It provides a thermal adjustement dial, a manual-automatic reset selector acting also as reset button, a trip test button for simulation of a tripping, a stop button, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D80-D95. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LA7D3064 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs\/Reach).\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD3357.pdf?v=1727349858\"\u003e\u003cp\u003eView More Details\u003c\/p\u003e\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46629867782384,"sku":"00102037","price":53.5,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD3357_Image_4000_d922d289-17b5-426d-8f5c-4e887c85a46f.png?v=1727603237"},{"product_id":"thermal-overload-relay-tesys-deca-690vac-37-to-50a-1no1nc-class-10a-everlink-btr-screw","title":"Thermal overload relay, TeSys Deca, 690VAC, 37 to 50A, 1NO+1NC, class 10A, EverLink BTR screw","description":"TeSys LRD thermal overload relay, 50A\/690V, thermal setting range 37-50A, tripping class 10A, for protection of 3-phase motors 22kW@400V. Differential device with phase failure (loss). It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by EverLink BTR screw terminals , it connects directly to the bottom terminals of 3-pole contactors LC1D40A-D80A. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD96560 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHs\/Reach).\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD350.pdf?v=1727349908\"\u003e\u003cp\u003eView More Details\u003c\/p\u003e\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46629867913456,"sku":"00102038","price":55.8,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD350_Image_4000_6299a1ac-1fbc-494b-9ddf-6a62524711cf.png?v=1727603243"},{"product_id":"thermal-overload-relays-tesys-deca-48-65-a-class-10a","title":"Thermal overload relays, TeSys Deca, 48...65 A , class 10A","description":"TeSys LRD thermal overload relay, 65A\/1000V, thermal setting range 48-65A, tripping class 10A, for protection of 3-phase motors 30kW@400V. Differential device with phase failure (loss). It provides a thermal adjustement dial, a manual-automatic reset selector acting also as reset button, a trip test button for simulation of a tripping, a stop button, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D80-D95. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LA7D3064 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs\/Reach).\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD3359.pdf?v=1727349991\"\u003e\u003cp\u003eView More Details\u003c\/p\u003e\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46629868011760,"sku":"00102039","price":53.45,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD3359_Image_4000_42bb757e-8336-4437-a891-873a5673f725.png?v=1727603251"},{"product_id":"thermal-overload-relay-tesys-deca-690vac-48-to-65a-1no1nc-class-10a-everlink-btr-screw","title":"Thermal overload relay, TeSys Deca, 690VAC, 48 to 65A, 1NO+1NC, class 10A, EverLink BTR screw","description":"TeSys LRD thermal overload relay, 65A\/690V, thermal setting range 48-65A, tripping class 10A, for protection of 3-phase motors 30kW@400V. Differential device with phase failure (loss). It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by EverLink BTR screw terminals , it connects directly to the bottom terminals of 3-pole contactors LC1D40A-D80A. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD96560 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHs\/Reach).\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD365.pdf?v=1727350062\"\u003e\u003cp\u003eView More Details\u003c\/p\u003e\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46629868077296,"sku":"00102040","price":58.15,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD365_Image_4000_43f45d9f-d07f-4a96-a677-54448efc32bf.png?v=1727603257"},{"product_id":"thermal-overload-relays-tesys-deca-55-70-a-class-10a","title":"Thermal overload relays, TeSys Deca, 55...70 A , class 10A","description":"TeSys LRD thermal overload relay, 70A\/1000V, thermal setting range 55-70A, tripping class 10A, for protection of 3-phase motors 37kW@400V. Differential device with phase failure (loss). It provides a thermal adjustement dial, a manual-automatic reset selector acting also as reset button, a trip test button for simulation of a tripping, a stop button, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D80-D95. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LA7D3064 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs\/Reach).\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD3361.pdf?v=1727350107\"\u003e\u003cp\u003eView More Details\u003c\/p\u003e\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46629868110064,"sku":"00102042","price":64.0,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD3361_Image_4000_bbdb96de-a96c-4cc3-86e0-a4143de474e8.png?v=1727603265"},{"product_id":"thermal-overload-relays-tesys-deca-63-80a-class-10a","title":"Thermal overload relays, TeSys Deca, 63...80A, class 10A","description":"\u003cp\u003eTeSys LRD thermal overload relay, 80A\/1000V, thermal setting range 63-80A, tripping class 10A, for protection of 3-phase motors 37kW@400V. Differential device with phase failure (loss). It provides a thermal adjustement dial, a manual-automatic reset selector acting also as reset button, a trip test button for simulation of a tripping, a stop button, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D80-D95. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LA7D3064 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs\/Reach).\u003c\/p\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD3363.pdf?v=1727350140\"\u003e\n\u003cp\u003eView More Details\u003c\/p\u003e\n\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46629868142832,"sku":"00102043","price":84.15,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD3363_Image_4000_d4ce8ddf-3dfd-4d6d-93fd-c7371329bea8.png?v=1727603274"},{"product_id":"thermal-overload-relays-tesys-deca-80-104a-class-10a-motor-protection","title":"Thermal overload relays, TeSys Deca, 80...104A, class 10A, motor protection","description":"TeSys LRD thermal overload relay, 104A\/1000V, thermal setting range 80-104A, tripping class 10A, for protection of 3-phase motors 45kW@400V. Differential device with phase failure (loss). It provides a thermal adjustement dial, a manual-automatic reset selector acting also as reset button, a trip test button for simulation of a tripping, a stop button, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D80-D95. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LA7D3064 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs\/Reach).\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD3365.pdf?v=1727350177\"\u003e\u003cp\u003eView More Details\u003c\/p\u003e\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46629871124720,"sku":"00102045","price":84.15,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD3365_Image_4000_3e92e788-8895-40f1-bad9-eee4e75d278b.png?v=1727603283"},{"product_id":"thermal-overload-relays-tesys-deca-110-140a-class-10a-lug-clamps","title":"Thermal overload relays, TeSys Deca, 110...140A, class 10A, lug clamps","description":"TeSys LRD thermal overload relay, 140A\/1000V, thermal setting range 110-140A, tripping class 10A, for protection of 3-phase motors 75kW@400V. Differential device with phase failure (loss). It provides a thermal adjustement dial, a manual-automatic reset selector acting also as reset button, a trip test button for simulation of a tripping, a stop button, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D150. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LA7D3064 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs\/Reach).\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD4369.pdf?v=1727350220\"\u003e\u003cp\u003eView More Details\u003c\/p\u003e\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46629871157488,"sku":"00102047","price":99.5,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD4369_Image_4000_3db9665b-3ca3-4a53-b962-93055551c456.png?v=1727603289"},{"product_id":"thermal-overload-relays-tesys-deca-95-120a-class-10a-lug-clamps","title":"Thermal overload relays, TeSys Deca, 95...120A, class 10A, lug clamps","description":"TeSys LRD thermal overload relay, 120A\/1000V, thermal setting range 95-120A, tripping class 10A, for protection of 3-phase motors 55kW@400V. Differential device with phase failure (loss). It provides a thermal adjustement dial, a manual-automatic reset selector acting also as reset button, a trip test button for simulation of a tripping, a stop button, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D115-D150. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LA7D3064 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs\/Reach).\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD4367.pdf?v=1727350255\"\u003e\u003cp\u003eView More Details\u003c\/p\u003e\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46629871223024,"sku":"00102049","price":99.5,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD4367_Image_4000_6ed3ff21-83bb-4206-921d-1844a665d6e2.png?v=1727603296"},{"product_id":"thermal-overload-relays-tesys-deca-80-104a-class-10a-lug-clamps","title":"Thermal overload relays, TeSys Deca, 80...104A, class 10A, lug clamps","description":"TeSys LRD thermal overload relay, 104A\/1000V, thermal setting range 80-104A, tripping class 10A, for protection of 3-phase motors 45kW@400V. Differential device with phase failure (loss). It provides a thermal adjustement dial, a manual-automatic reset selector acting also as reset button, a trip test button for simulation of a tripping, a stop button, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D115-D150. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LA7D3064 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs\/Reach).\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD4365.pdf?v=1727350295\"\u003e\u003cp\u003eView More Details\u003c\/p\u003e\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46629871288560,"sku":"00102050","price":99.5,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LRD4365_Image_4000_901188dc-c6ac-4394-99f3-753da339a95d.png?v=1727603302"},{"product_id":"tesys-lrf-electronic-thermal-overload-relay-90-150-a-class-10","title":"TeSys LRF - electronic thermal overload relay - 90...150 A - class 10","description":"TeSys LR9F electronic overload relay, thermal setting range 90-150A, class 10, for protection of motors 55-75kW@400V. to be mounted directly below a TeSys F 3-pole contactor LC1 F115, F150, F185, use of a support mounting plate LA7F901 is recommended (to be ordered separately). Motor protection includes thermal overload of 1-phase and 3-phase motors, phase failure, phase unbalance, prolonged starting times, stalled rotor conditions. On the front of the relay, it provides a thermal adjustment dial, buttons for test, stop \u0026amp; reset, a trip indicator, trip auxiliary contacts 1NO+1NC. Multi standards certified (IEC, UL, CSA, CCC, Marine), Green Premium compliant (RoHs\/Reach).\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LR9F5369.pdf?v=1727350341\"\u003e\u003cp\u003eView More Details\u003c\/p\u003e\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46629871354096,"sku":"00102051","price":194.0,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/00102051.jpg?v=1762177448"},{"product_id":"tesys-lrf-electronic-thermal-overload-relay-200-330-a-class-10","title":"TeSys LRF - electronic thermal overload relay - 200...330 A - class 10","description":"TeSys LR9F electronic overload relay, thermal setting range 200-330A, class 10, for protection of motors 132-160kW@400V. to be mounted directly below a TeSys F 3-pole contactor LC1 F225, F265, F330, F400, F500, use of a support mounting plate LA7F902 is mandatory (to be ordered separately). Motor protection includes thermal overload of 1-phase and 3-phase motors, phase failure, phase unbalance, prolonged starting times, stalled rotor conditions. On the front of the relay, it provides a thermal adjustement dial, buttons for test, stop \u0026amp; reset, a trip indicator, trip auxiliary contacts 1NO+1NC. Multi standards certified (IEC, UL, CSA, CCC, Marine), Green Premium compliant (RoHs\/Reach).\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LR9F7375.pdf?v=1727350377\"\u003e\u003cp\u003eView More Details\u003c\/p\u003e\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46629871386864,"sku":"00102055","price":301.0,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/PB111600_4000_3dcb77a1-3ebb-4f26-a380-fdf715c55555.png?v=1727603310"},{"product_id":"tesys-lrf-electronic-thermal-overload-relay-300-500-a-class-10","title":"TeSys LRF - electronic thermal overload relay - 300...500 A - class 10","description":"TeSys LR9F electronic overload relay, thermal setting range 300-500A, class 10, for protection of motors 200-250kW@400V. to be mounted directly below a TeSys F 3-pole contactor LC1 F225, F265, F330, F400, F500, use of a support mounting plate LA7F902 is mandatory (to be ordered separately). Motor protection includes thermal overload of 1-phase and 3-phase motors, phase failure, phase unbalance, prolonged starting times, stalled rotor conditions. On the front of the relay, it provides a thermal adjustement dial, buttons for test, stop \u0026amp; reset, a trip indicator, trip auxiliary contacts 1NO+1NC. Multi standards certified (IEC, UL, CSA, CCC, Marine), Green Premium compliant (RoHs\/Reach).\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LR9F7379.pdf?v=1727350430\"\u003e\u003cp\u003eView More Details\u003c\/p\u003e\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46629871452400,"sku":"00102057","price":394.0,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/PB111600_4000_1_38ecfabf-7edd-4cf4-b219-1606ea2fd75f.png?v=1727603315"},{"product_id":"differential-thermal-overload-relay-tesys-k-0-8-1-2a-class-10a","title":"Differential thermal overload relay, TeSys K, 0.8...1.2A, class 10A","description":"\u003cp\u003eTeSys LRK thermal overload relay, 1.2A\/690V, thermal setting range 0.8-1.2A, tripping class 10A, for protection of 3-phase motors 0.25-0.37kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test slide switch for simulation of a tripping, reset\/stop button, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1K06-K16. Mounting on DIN rail, separated from the contactor, with use of a terminal block LA7K0064 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHs\/Reach).\u003c\/p\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LR2K0306.pdf?v=1727350458\"\u003e\n\u003cp\u003eView More Details\u003c\/p\u003e\n\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46629871485168,"sku":"00102058","price":21.0,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LR2K0306_Image_4000_aaf029b7-213c-40a7-943b-d3206b1ceea9.png?v=1727603320"},{"product_id":"differential-thermal-overload-relay-tesys-k-1-2-1-8a-class-10a","title":"Differential thermal overload relay, TeSys K, 1.2...1.8A, class 10A","description":"\u003cp\u003eTeSys LRK thermal overload relay, 1.8A\/690V, thermal setting range 1.2-1.8A, tripping class 10A, for protection of 3-phase motors 0.55kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test slide switch for simulation of a tripping, reset\/stop button, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1K06-K16. Mounting on DIN rail, separated from the contactor, with use of a terminal block LA7K0064 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHs\/Reach).\u003c\/p\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LR2K0307.pdf?v=1727350490\"\u003e\n\u003cp\u003eView More Details\u003c\/p\u003e\n\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46629871583472,"sku":"00102059","price":21.0,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LR2K0307_Image_4000_e3b98310-2d31-470c-a5b8-00105a9201d1.png?v=1727603326"},{"product_id":"differential-thermal-overload-relay-tesys-k-1-8-2-6a-class-10a","title":"Differential thermal overload relay, TeSys K, 1.8...2.6A, class 10A","description":"TeSys LRK thermal overload relay, 2.6A\/690V, thermal setting range 1.8-2.6A, tripping class 10A, for protection of 3-phase motors 0.75kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test slide switch for simulation of a tripping, reset\/stop button, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1K06-K16. Mounting on DIN rail, separated from the contactor, with use of a terminal block LA7K0064 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHs\/Reach).\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LR2K0308.pdf?v=1727350538\"\u003e\u003cp\u003eView More Details\u003c\/p\u003e\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46629871649008,"sku":"00102060","price":21.0,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LR2K0308_Image_4000_8cac0148-8cb8-423f-b2a7-38de51dcd267.png?v=1727603333"},{"product_id":"differential-thermal-overload-relay-tesys-k-2-6-3-7a-class-10a","title":"Differential thermal overload relay, TeSys K, 2.6...3.7A, class 10A","description":"\u003cp\u003eTeSys LRK thermal overload relay, 3.7A\/690V, thermal setting range 2.6-3.7A, tripping class 10A, for protection of 3-phase motors 1.1-1.5kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test slide switch for simulation of a tripping, reset\/stop button, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1K06-K16. Mounting on DIN rail, separated from the contactor, with use of a terminal block LA7K0064 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHs\/Reach).\u003c\/p\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LR2K0310.pdf?v=1727350582\"\u003e\n\u003cp\u003eView More Details\u003c\/p\u003e\n\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46629871714544,"sku":"00102061","price":21.0,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LR2K0310_Image_4000_9f1ac9f2-3a96-45bd-abf4-0f4557e73599.png?v=1727603338"},{"product_id":"differential-thermal-overload-relay-tesys-k-3-7-5-5a-class-10a","title":"Differential thermal overload relay, TeSys K, 3.7...5.5A, class 10A","description":"\u003cp\u003eTeSys LRK thermal overload relay, 5.5A\/690V, thermal setting range 3.7-5.5A, tripping class 10A, for protection of 3-phase motors 2.2kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test slide switch for simulation of a tripping, reset\/stop button, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1K06-K16. Mounting on DIN rail, separated from the contactor, with use of a terminal block LA7K0064 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHs\/Reach).\u003c\/p\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LR2K0312.pdf?v=1727350621\"\u003e\n\u003cp\u003eView More Details\u003c\/p\u003e\n\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46629871780080,"sku":"00102062","price":21.0,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LR2K0312_Image_4000_b470a80d-d5f2-4b12-9051-caed3262e002.png?v=1727603344"},{"product_id":"differential-thermal-overload-relay-tesys-k-5-5-8a-class-10a","title":"Differential thermal overload relay, TeSys K, 5.5...8A, class 10A","description":"\u003cp\u003eTeSys LRK thermal overload relay, 8A\/690V, thermal setting range 5.5-8A, tripping class 10A, for protection of 3-phase motors 3kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test slide switch for simulation of a tripping, reset\/stop button, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1K09-K16. Mounting on DIN rail, separated from the contactor, with use of a terminal block LA7K0064 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHs\/Reach).\u003c\/p\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LR2K0314.pdf?v=1727350650\"\u003e\n\u003cp\u003eView More Details\u003c\/p\u003e\n\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46629871812848,"sku":"00102063","price":21.0,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LR2K0314_Image_4000_9556b2cd-ad2f-4287-8de5-456f2a91825e.png?v=1727603350"},{"product_id":"adapter-terminal-block-tesys-deca-for-separate-mounting-of-lrd01-d35-lr3d02-d35-lr97d","title":"TeSys D thermal overload relays - terminal block","description":"\u003cp\u003eTeSys LRD terminal block for mounting of thermal overload relays LRD01-D35, LR3D01-D35 and electronic overcurrent relays LR97D. To be used for a separate mounting between overload relay and contactor. It provides top connections with screw clamp terminals, clip-on fixing on 35 mm DIN-rail or fixing by screws. Green Premium compliant (RoHS\/REACh).\u003c\/p\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LAD7B106.pdf?v=1727350859\"\u003e\n\u003cp\u003eView More Details\u003c\/p\u003e\n\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46629871878384,"sku":"00102071","price":7.4,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LAD7B106_Image_4000_d7c08ab6-812e-4766-b613-6bdde0765323.png?v=1727603359"},{"product_id":"adapter-terminal-block-tesys-deca-for-separate-mounting-of-lrd33-lr2d3-lr3d3","title":"Adapter terminal block,TeSys Deca,for separate mounting of LRD33...LR2D3...LR3D3","description":"\u003cp\u003eTeSys LRD terminal block, for thermal overload relays LRD33**, LR3D33**, LR2D35**. To be used for a separate mounting of overload relay and contactor. It provides top connections by screw clamp terminals, clip-on fixing on 35 mm DIN-rail or fixing by screws. Green Premium compliant (RoHS\/REACh).\u003c\/p\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LA7D3064.pdf?v=1727350911\"\u003e\n\u003cp\u003eView More Details\u003c\/p\u003e\n\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46629871976688,"sku":"00102073","price":21.9,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LA7D3064_Image_4000_70e00fb7-f987-415a-a827-a2a7e30d8df2.png?v=1727603367"},{"product_id":"terminal-block-tesys-deca-everlink-btr-screw-connectors-3p-for-contactors-lc1d40a-d80a","title":"Terminal block, TeSys Deca, Everlink BTR screw connectors, 3P, for contactors LC1D40A-D80A","description":"\u003cp\u003eTeSys D terminal block, for mounting on LRD3xx, LR3D3xx thermal overload relays or as replacement part, for 3-pole contactors LC1D40A-D80A. It provides connection by EverLink BTR screw terminals. It ensures an IP20 protection on front. Green Premium compliant (RoHS\/REACh).\u003c\/p\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LAD96560.pdf?v=1727350943\"\u003e\n\u003cp\u003eView More Details\u003c\/p\u003e\n\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46629872009456,"sku":"00102074","price":7.4,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/LAD96560_Image_web_affd25b2-77af-4fe1-8c24-e9ae33d554a5.jpg?v=1727603369"},{"product_id":"electronic-overcurrent-relay-tesys-lr97d-200-to-240vac-1-2-to-7a-1c-o","title":"Electronic overcurrent relay, TeSys LR97D, 200 to 240VAC, 1.2 to 7A, 1C\/O","description":"\u003cp\u003eTeSys LR97D electronic overcurrent relay, 7A\/690V, to be supplied with 200-240V AC, for protection of motors with a rated current 1.2-6A. It provides 3 dials to adjust the protection, LOAD (1.2-7A) for the overcurrent level, O-TIME (0.3-10sec) for the acceptable duration of the overcurrent, D-TIME (0.5-30sec) for the starting duration. In addition, the device trips when the current is higher than 3 x LOAD during more than 0.5sec in steady state and if there is a missing phase during more than 3sec. Settings also include selectors for 1-phase\/3-phase motors and manual\/automatic reset, the device has a reset button, a test\/stop button, 2 LED indicators (Run\/Trip), 2 auxiliary contacts 1NO\/NC for fault signaling. Settings can be locked by sealing the transparent cover. For direct attachment to the bottom terminals of a 3-phase contactor LC1D09-D38, with screw clamp terminals on bottom, the separate mounting from the contactor is possible using the terminal block LAD7B106 (to be ordered separately). Multi-standards certified (IEC, UL, CSA, CCC, EAC), compliant RoHs\/Reach.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46667003625712,"sku":"00112010","price":55.5,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/00112010.jpg?v=1762177644"},{"product_id":"electronic-overcurrent-relay-tesys-lr97d-200-to-240vac-20-to-38a-1c-o","title":"Electronic overcurrent relay, TeSys LR97D, 200 to 240VAC, 20 to 38A, 1C\/O","description":"\u003cp\u003eTeSys LR97D electronic overcurrent relay, 38A\/690V, to be supplied with 200-240V AC, for protection of motors with a rated current 20-34A. It provides 3 dials to adjust the protection, LOAD (20-38A) for the overcurrent level, O-TIME (0.3-10sec) for the acceptable duration of the overcurrent, D-TIME (0.5-30sec) for the starting duration. In addition, the device trips when the current is higher than 3 x LOAD during more than 0.5sec in steady state and if there is a missing phase during more than 3sec. The settings include selectors for 1-phase\/3-phase motors and manual\/automatic reset, and the device has a reset button, a test\/stop button, 2 LED indicators (Run\/Trip), 2 auxiliary contacts 1NO\/NC for fault signalling. Settings can be locked by sealing the transparent cover. For direct attachement to the bottom terminals of a 3-pole contactor LC1D25-D38, with screw clamp terminals on bottom, the separate mounting from the contactor is possible using the terminal block LAD7B106 (to be ordered separately). Multi-standards certified (IEC, UL, CSA, CCC, EAC), compliant RoHs\/Reach.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46667003756784,"sku":"00112012","price":0.0,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/00112012.jpg?v=1762177645"},{"product_id":"thermal-overload-relay-0-63-1a","title":"Thermal Overload Relay 0.63-1A","description":"JR28s series thermal overload relay are suitable for overload and phase-failure protection of AC motors with frequency of 50\/60Hz,\n voltage up to 690V, current up to 0.1-630A under 8-hours duty or uninterrupted duty.\n Functions provided by these relays, are phase-failure protection, ON\/OFF indication, temperature compensation, and manual\/\n automatic reset.\n International Standard: IEC 60947-4-1\n The relays can be mounted onto contactors or installed as single units\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/JR28-JR28s-series-Instructions-22.12.9.pdf?v=1752076165\"\u003e\u003cp\u003e More Product Details\u003c\/p\u003e\u003c\/a\u003e","brand":"CNC Electric","offers":[{"title":"Default Title","offer_id":47807841894640,"sku":"05302003","price":8.25,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/14_3ac55be0-5f0d-4a88-a98f-d5df3d831b9a.jpg?v=1752226766"},{"product_id":"thermal-overload-relay-1-1-6a","title":"Thermal Overload Relay 1-1.6A","description":"JR28s series thermal overload relay are suitable for overload and phase-failure protection of AC motors with frequency of 50\/60Hz,\n voltage up to 690V, current up to 0.1-630A under 8-hours duty or uninterrupted duty.\n Functions provided by these relays, are phase-failure protection, ON\/OFF indication, temperature compensation, and manual\/\n automatic reset.\n International Standard: IEC 60947-4-1\n The relays can be mounted onto contactors or installed as single units\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/JR28-JR28s-series-Instructions-22.12.9.pdf?v=1752076165\"\u003e\u003cp\u003e More Product Details\u003c\/p\u003e\u003c\/a\u003e","brand":"CNC Electric","offers":[{"title":"Default Title","offer_id":47807841927408,"sku":"05302004","price":8.25,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/14_a9f49429-b1df-4e92-8be4-afc4ef3c0f98.jpg?v=1752226767"},{"product_id":"thermal-overload-relay-1-6-2-5a","title":"Thermal Overload Relay 1.6-2.5A","description":"JR28s series thermal overload relay are suitable for overload and phase-failure protection of AC motors with frequency of 50\/60Hz,\n voltage up to 690V, current up to 0.1-630A under 8-hours duty or uninterrupted duty.\n Functions provided by these relays, are phase-failure protection, ON\/OFF indication, temperature compensation, and manual\/\n automatic reset.\n International Standard: IEC 60947-4-1\n The relays can be mounted onto contactors or installed as single units\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/JR28-JR28s-series-Instructions-22.12.9.pdf?v=1752076165\"\u003e\u003cp\u003e More Product Details\u003c\/p\u003e\u003c\/a\u003e","brand":"CNC Electric","offers":[{"title":"Default Title","offer_id":47807841960176,"sku":"05302005","price":8.25,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/14_2d922ffe-2e20-4def-818f-f650a22dfa33.jpg?v=1752226769"},{"product_id":"thermal-overload-relay-2-5-4a","title":"Thermal Overload Relay 2.5-4A","description":"JR28s series thermal overload relay are suitable for overload and phase-failure protection of AC motors with frequency of 50\/60Hz,\n voltage up to 690V, current up to 0.1-630A under 8-hours duty or uninterrupted duty.\n Functions provided by these relays, are phase-failure protection, ON\/OFF indication, temperature compensation, and manual\/\n automatic reset.\n International Standard: IEC 60947-4-1\n The relays can be mounted onto contactors or installed as single units\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/JR28-JR28s-series-Instructions-22.12.9.pdf?v=1752076165\"\u003e\u003cp\u003e More Product Details\u003c\/p\u003e\u003c\/a\u003e","brand":"CNC Electric","offers":[{"title":"Default Title","offer_id":47807842025712,"sku":"05302006","price":8.25,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/14_14d1bbe6-ef42-41ed-882b-21e8c604a2ad.jpg?v=1752226771"},{"product_id":"thermal-overload-relay-4-6a","title":"Thermal Overload Relay 4-6A","description":"JR28s series thermal overload relay are suitable for overload and phase-failure protection of AC motors with frequency of 50\/60Hz,\n voltage up to 690V, current up to 0.1-630A under 8-hours duty or uninterrupted duty.\n Functions provided by these relays, are phase-failure protection, ON\/OFF indication, temperature compensation, and manual\/\n automatic reset.\n International Standard: IEC 60947-4-1\n The relays can be mounted onto contactors or installed as single units\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/JR28-JR28s-series-Instructions-22.12.9.pdf?v=1752076165\"\u003e\u003cp\u003e More Product Details\u003c\/p\u003e\u003c\/a\u003e","brand":"CNC Electric","offers":[{"title":"Default Title","offer_id":47807842058480,"sku":"05302007","price":8.25,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/14_e6277a96-51bb-4337-9418-0564cf321b1f.jpg?v=1752226772"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/collections\/LRD01_Image_AI-improved_2024_369.jpg?v=1759743117","url":"https:\/\/obaido.com\/collections\/overload-relays.oembed?page=2","provider":"Obaido","version":"1.0","type":"link"}