{"title":"أجهزة مراقبة العزل الكهربائي","description":"","products":[{"product_id":"closed-toroid-a-type-for-vigirex-and-vigilhom-pa50-inner-diameter-50-mm-rated-current-85-a","title":"Closed toroid A type, for Vigirex and Vigilhom, PA50, inner diameter 50 mm, rated current 85 A","description":"This toroid is dedicated to Vigilohm Insulation Fault locators, and to VigiPacT type A residual current protection and monitoring relays. It allows the monitoring of the injected component from Vigilohm Insulation Monitor, and the measurement of a current rating up to 85A for VigiPacT monitoring and protection relays. The transformer ratio is 1\/1000.\n\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/50438.pdf?v=1728891693\"\u003e\u003cp\u003eView More Details\u003c\/p\u003e\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46682117144816,"sku":"00261067","price":0.0,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/00261067.jpg?v=1762182025"},{"product_id":"closed-toroid-a-type-vigipact-vigilohm-ma120-inner-diameter-120mm-rated-current-250a","title":"Closed toroid A type, VigiPacT, Vigilohm, MA120, inner diameter 120mm, rated current 250A.","description":"This toroid is dedicated to Vigilohm Insulation Fault locators, and to VigiPacT type A residual current protection and monitoring relays. It allows the monitoring of the injected component from Vigilohm Insulation Monitor, and the measurement of a current rating up to 250A for VigiPacT monitoring and protection relays. The transformer ratio is 1\/1000. The inner diameter of the toroid is 120 millimeters and the weight is 0.450kg. The cables must be centered within the toroid and the diameter represented by all these cables should not exceed 60 millimeters. The maximum cross section per phase (R, S, T, N) is 240mm_ for a copper conductor.\n\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/50440.pdf?v=1728891738\"\u003e\u003cp\u003eView More Details\u003c\/p\u003e\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46682117177584,"sku":"00261068","price":0.0,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/00261068.jpg?v=1762182027"},{"product_id":"closed-toroid-a-type-for-vigirex-and-vigilhom-sa200-inner-diameter-200-mm-rated-current-400-a","title":"Closed toroid A type, for Vigirex and Vigilhom, SA200, inner diameter 200 mm, rated current 400 A","description":"This toroid is dedicated to Vigilohm Insulation Fault locators, and to VigiPacT type A residual current protection and monitoring relays. It allows the monitoring of the injected component from Vigilohm Insulation Monitor, and the measurement of a current rating up to 400A for VigiPacT monitoring and protection relays. The transformer ratio is 1\/1000. The inner diameter of the toroid is 200 millimeters and the weight is 1.320kg. The cables must be centered within the toroid and the diameter represented by all these cables should not exceed 100 millimeters. The maximum cross section per phase (R, S, T, N) is 2 cables of 185mm_ for a copper conductor.\n\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/50441.pdf?v=1728891797\"\u003e\u003cp\u003eView More Details\u003c\/p\u003e\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46682117243120,"sku":"00261069","price":0.0,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/00261069.jpg?v=1762182028"},{"product_id":"closed-toroid-for-residual-current-protection-ga-o-300-mm","title":"Closed toroid for residual current protection GA - ¿ 300 mm","description":"This toroid is dedicated to Vigilohm Insulation Fault locators, and to VigiPacT type A residual current protection and monitoring relays. It allows the monitoring of the injected component from Vigilohm Insulation Monitor, and the measurement of a current rating up to 630A for VigiPacT monitoring and protection relays. The transformer ratio is 1\/1000. The inner diameter of the toroid is 300 millimeters and the weight is 2.280kg. The cables must be centered within the toroid and the diameter represented by all these cables should not exceed 150 millimeters. The maximum cross section per phase (R, S, T, N) is 2 cables of 240mm_ for a copper conductor.\n\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/50442.pdf?v=1728891832\"\u003e\u003cp\u003eView More Details\u003c\/p\u003e\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46682117931248,"sku":"00261070","price":0.0,"currency_code":"JOD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/00261070.jpg?v=1762182029"},{"product_id":"closed-toroid-a-type-vigipact-vigilohm-ia80-inner-diameter-80mm-rated-current-160a","title":"Closed toroid A type, VigiPacT, Vigilohm, IA80, inner diameter 80mm, rated current 160A","description":"This toroid is dedicated to Vigilohm Insulation Fault locators, and to VigiPacT type A residual current protection and monitoring relays. It allows the monitoring of the injected component from Vigilohm Insulation Monitor, and the measurement of a current rating up to 160A for VigiPacT monitoring and protection relays. The transformer ratio is 1\/1000. The inner diameter of the toroid is 80 millimeters and the weight is 0.420kg. The cables must be centered within the toroid and the diameter represented by all these cables should not exceed 40 millimeters. The maximum cross section per phase (R, S, T, N) is 95mm_ for a copper conductor.\n\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/50439.pdf?v=1728891870\"\u003e\u003cp\u003eView More Details\u003c\/p\u003e\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46682117964016,"sku":"00261095","price":0.0,"currency_code":"JOD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/00261095.jpg?v=1762182031"},{"product_id":"closed-toroid-a-type-for-vigirex-and-vigilhom-ta30-inner-diameter-30-mm-rated-current-65-a","title":"Closed toroid A type, for Vigirex and Vigilhom, TA30, inner diameter 30 mm, rated current 65 A","description":"This toroid is dedicated to Vigilohm Insulation Fault locators, and to VigiPacT type A residual current protection and monitoring relays. It allows the monitoring of the injected component from Vigilohm Insulation Monitor, and the measurement of a current rating up to 65A for VigiPacT monitoring and protection relays. The transformer ratio is 1\/1000.\n\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/50437.pdf?v=1728891903\"\u003e\u003cp\u003eView More Details\u003c\/p\u003e\u003c\/a\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":46682117996784,"sku":"00261099","price":0.0,"currency_code":"JOD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0719\/9109\/9632\/files\/00261099.jpg?v=1762182033"}],"url":"https:\/\/obaido.com\/ar\/collections\/insulation-monitors.oembed","provider":"Obaido","version":"1.0","type":"link"}